SUN EAST PEAK-350
电脑波峰焊用户手册
47 -74
Temperature Test
The soldering system is equipped with 3 wires for testing the temperature, so it can meet the
test needs of 3 points on PCB simultaneously. At first, the user can connect the test wires to the
surface of PCB and make the soldering system solders the PCB under high temperature. Be sure
that the test head has been covered completely. Make the soldering system on run, and connect
the testing wires with the socket of control panel, then input the PCB into the buffer of
conveyor system. Press
“
Test Start
”
button, the system will start testing the changes of
temperature and the temperature curve will show on this screen.
Press
“
Test Stop
”
button, the test on the system will stop.
Press
“
Temperature Parameter Setup
”
button for setting the required parameters
Press
“
Save
”
button for saving the test curves for later reference.
Press
“
Open
”
button for opening the temperature profile saved before.
Press
“
Temperature Reset
”
button for resetting the current temperature.
Press
“
Open
”
button for opening the temperature profile saved before.
4.5 Manual Operation
Press
“
Control Panel
”
menu on main menu or press the icon of
“
Control Panel
”
on tool bar to
open its dialog box.
Press
“
OFF
”
button of Automatic Mode, its green light will black out and the solder pot will not
be heated as per the preset time on inner timer. Press
“
ON
”
buttons for other functions for