Reference
N-10
®
Notes
10MAY01
Using An Anti-Seize Lubricant To Extend
The Life of FDM Liquefiers
Using an anti-seize lubricant will help extend the life of all models of FDM
liquefier. Applying a high temperature anti-seize lubricant to the FDM mod-
eler tip‘s threads will prevent cold welding of the tip to the steel threads of
the FDM Head.
Before applying the lubricant, review the following usage and application in-
structions. If necessary, refer to your FDM operations manual for additional
information on changing and inserting FDM tips into the FDM head.
Recommended Usage
Only use a light coat of an anti-seize lubricant when:
• you need to insert a new tip in a liquefier for the first time
or
• when you need to replace a tip with a new or used tip
Follow the standard tip removal procedures, as outlined in your FDM
documentation. Also, do not remove a tip only to apply the anti-seize
lubricant.
Recommended Application
• Be sure to apply the anti-seize lubricant to the tip’s threads
prior
to thread-
ing the tip into the liquefier.
• Apply the lubricate to the tip’s threads,
not
the aluminum threads within the
FDM head.
• Apply a
thin
coat of lubricant to the
grooves of the tip’s thread.
You don’t need to completely coat the
threads.
• If you apply too much, purge the excess
lubricant from the tip.
Note
: Use high temperature, anti-seize lubricants designed to prevent seizing,
galling, and corrosion. These lubricants are easily obtained from most automo-
bile parts and supply stores. If you have additional questions, please call
Stratasys Customer Service at 952-906-2283.
Apply a thin
layer of lubricant
to the tip's threads
Summary of Contents for FDM 2000
Page 1: ...Introduction FDM 2000 3000 8000 Release 2 0 Stratasys Document no 105208 0001 Rev B...
Page 17: ...Contents FDM 2000 3000 8000 Manual 10 MAY 01 F2 3 8000 vi...
Page 105: ...Reference N 2 Notes 10MAY01 Release 1 0 October 1997 5 0 May 2001...
Page 131: ...G 1 Reference Glossary 10MAY01 Release 4 0 Glossary Stratasys Document no 105213 0001 Rev B...