DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
81
9.2.8 Parameter Group 08 - Display Filters
The parameters in this group select the time constants for the digital filters used that are applied to
the load cell and output signals.
P 08.01 LC Filter
Default: 4.00 sec
Min: 0.25 sec
Max: 300.00 sec
This parameter sets the amount of digital filtering used on the load cell signals. It is similar to the
196NT Setup 19 Weight Signal Filter.
This parameter is normally set to 4 seconds.
P 08.02 I-Display
Default: 1.0 sec
Min: 0.0 sec
Max: 600.0 sec
This parameter sets the amount of digital filtering used on the feedrate value displayed on the display,
EasyServe and field bus interface. It is similar to the 196NT Setup 20 Feedback Signal Filter.
This parameter is normally set to 1 second.
P 08.03 I-Analog Output
Default: 1.0 sec
Min: 0.0 sec
Max: 600.0 sec
This parameter sets the amount of digital filtering used on the feedrate signal sent to the analog
output channel. It is similar to the 196NT Setup 20 Feedback Signal Filter. This parameter is
normally set to 1 second.
P 08.04 Feedback filter override threshold
Default: 15%
Min: 0.0%
Max: 200.0%
This parameter specifies point at which the point at which the feedback filter is overridden and the
actual feedrate is displayed. This is used so that large changes are displayed quickly. This parameter
is the same as 196NT Setup 21 (Feedback filter override threshold).
This parameter is normally set to 15%.
P 08.05 Belt Load
Default: 1.0 sec
Min: 0.0 sec
Max: 600.0 sec
This parameter sets the amount of digital filtering used on the belt load signal sent to the analog
output channel.
This parameter is normally set to 1 second.
Summary of Contents for DISOCONT Tersus DT-9
Page 2: ......
Page 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Page 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Page 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Page 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Page 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Page 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...