DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
113
P 16.05 DO: Feeder Run Forward 2
Default: n/a (not used - Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the second digital output used to start the feeder running forward. This
output is a duplicate of P 16.04 DO: Feeder Run Forward.
This function is not used and this parameter should be set to n/a (not used).
P 16.06 DO: Feeder Run Reverse
Default: DO 2 - High (Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the digital output used to start the feeder in reverse. This output is similar to
the K2 relay on the 196 NT.
This parameter must be set to DO 2 – High and is connected to wires 156-158.
P 16.07 DO: Feeder Run Reverse 2
Default: DO 3 - High (Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the second digital output used to start the feeder in reverse. This output is a
duplicate of P 16.06 DO: Feeder Run Reverse.
This parameter must be set to DO 3 – High and is connected to wires 159-161.
P 16.08 DO: Start Pre-feeder
Default: n/a (not used - Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the digital output used to start the pre-feeder.
This function is not used and this parameter should be set to n/a (not used).
Summary of Contents for DISOCONT Tersus DT-9
Page 2: ......
Page 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Page 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Page 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Page 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Page 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Page 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...