DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
32
5.2.2 The “Trend” Screen
The “Trend” screen is a customizable line graph that can be used to plot various data items that are
logged by the DT-9 over time. See Appendix C for a list of available data items.
5.2.3 The “Values” Screen
The “Values” screen displays information about the feeder on two sub screens, which can be
accessed by pressing the [Values] or [Totals] buttons.
The [Totals] button displays the following data:
•
Material Total
is the total amount of material delivered by the feeder, and is the sum of the
Gravimetric and Volumetric Totals.
•
Gravimetric Total
is the total amount of material delivered by the feeder while operating in
Gravimetric Mode.
•
Volumetric Total
is the total amount of material delivered by the feeder while operating in
Volumetric Mode.
•
The [Reset] button will reset all three totalizers. The total values cannot be recovered after
the [Reset] button is pressed.
The [Values] button displays the following data:
•
Belt Speed
shows the current speed of the belt in feet or meters per second.
•
Belt Load
shows the weight of the material on the belt per unit of belt length in pounds per
foot or kilograms per meter.
•
Speed
shows the shaft speed of the belt drive motor in revolutions per minute.
•
Density
shows the currently calculated density of the material on the belt in pounds per cubic
foot or kilograms per cubic meter.
5.2.4 The “Setup” Screen
The “Setup” Screen is used to configure the DT-9 and to access the various log files that are stored
by the controller.
The following buttons are initially shown on the “Setup” screen: [Data Log], [Event Log], [Param Log],
[Parameter], and [
] (Right Arrow).
Pressing the Right Arrow button causes the display to scroll to the following additional buttons: [Trim],
[Defaults], [Simulation], [Calibration], and [Set Time]. Pressing the Right Arrow button again will cause
the display to scroll back to the initial list of buttons.
The [Trim], [Defaults], and [Calibration] buttons will be grayed out and unavailable unless the user is
logged in to the DT-9. The user must also log in before changing any of the parameters that are
accessed via the [Parameter] button.
Summary of Contents for DISOCONT Tersus DT-9
Page 2: ......
Page 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Page 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Page 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Page 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Page 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Page 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...