10 Event (Error) Messages
Event messages report abnormal states, e.g. errors or limit value excess.
Always correct the cause of a fault before acknowledging it. The feeder has the potential to cause
injuries or damage if this procedure is not followed.
There are four different event classes:
Event Class
Code
Display / Effect
Alarm
A
All measuring and control operations are aborted.
System goes to safe state. This type of event is the
same as a feeder trip on the 196NT.
Warning 1
W1
The event is annunciated and remains active until it
has been acknowledged. Measuring and control
tasks are not affected. This type of event is similar to
some type of alarms on the 196NT
Warning 2
W2
The event is annunciated and remains active until
the cause has been corrected. It is not necessary to
acknowledge this type of event. Measuring and
control tasks are not affected. This type of event is
similar to some type of alarms on the 196NT
Ignore
IG
Event is not annunciated. Measuring and control
tasks are not affected.
Event are classified in the following groups with the priority shown.
Event Group
Symbol
System message
SY
Sequence monitoring
SC
Electrical system
WE
Mechanical system
WM
Material flow
MF
Interlocking
IL
Controllers
CO
Calibration
CA
Maximum
HI
Minimum
LO
Summary of Contents for DISOCONT Tersus DT-9
Page 2: ......
Page 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Page 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Page 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Page 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Page 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Page 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...