DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
118
P 16.25 DO: Remote CTRL
Default: DO 4 High (Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the digital output used to indicate that the feeder is in remote mode. This
output is similar to the Kx relay on the 196 NT.
This parameter must be set to DO 4 – High and is connected to wires 162-164.
P 16.26 DO: Remote CTRL 2
Default: n/a (not used - Hidden)
Options:
n/a (not used)
DO 1 thru DO 13 - High/Low
Normally Hidden.
This parameter specifies the digital output used to indicate that the feeder is in remote mode. This
output is a duplicate of P 16.25 DO: Remote CTRL.
This function is not used and this parameter should be set to n/a (not used).