DISOCONT® Tersus (DT-9) Configuration and Operations Manual
©Schenck Process Group
58
9.2.2 Parameter Group 02 - Feeder Definitions
Parameters in this group are used to select display formats and control some of the basic feeder
output signals.
P 02.01 Language
Default: ENGLISH
Options:
DEUTSCH
ENGLISH
OTHER
This parameter selects the language used in DT-9 displays. When it is set to “OTHER” the individual
display strings can be set using EasyServe.
P 02.02 Units
Default: English
Options:
Metric
English
This parameter selects the units used for displays and parameter inputs. Either SI (metric) or normal
American (English) units may be selected. The table below shows the conversion factors that are
used.
English unit
Metric
Conversion
pound lb
Kilogram kg
1 lb = 0.453593 kg
ton t
Metric Ton t
1 t = 0.907185 t = 2000 lb
feet f
Meter m
1 f = 0.3048 m
inch "
Millimeter mm
1" = 25.4 mm
The same values are used for combination units (e.g., kg/hr.)
P 02.03 Scale Name
Default: DT-9 – VCU20103
This parameter specifies the text string to identify the feeder and is shown on the top line of the touch
screen HMI.
This parameter is set according to customer preference.
P 02.04 Password
Default: 7353 (Displayed as 10000)
Min: 1000
Max: 9999
This parameter specifies the password used to restrict access to various controller functions.
Note:
This parameter can be changed using EasyServe in the event that the password is lost.
Note:
Some functions may require and alternate password. The default value is 7354.
Summary of Contents for DISOCONT Tersus DT-9
Page 2: ......
Page 8: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 6 ...
Page 30: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 28 ...
Page 40: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 38 ...
Page 50: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 48 ...
Page 150: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 148 ...
Page 154: ...DISOCONT Tersus DT 9 Configuration and Operations Manual Schenck Process Group 152 ...