10 | Connection
STOBER
130
02/2019 | ID 442728.05
10.5.14 X101: BE1 – BE4
The binary inputs 1 to 4 are available on terminal X101.
X101 for binary signals
For evaluating binary signals at X101, note the specification for the binary inputs in the technical
data of the drive controller, see the chapter
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
Binary inputs
2
BE2
3
BE3
4
BE4
5
DGND
Reference ground; not bridged with X103, pin
5
Tab. 124: X101 connection description for binary signals
X101 for encoders
If you would like to use X101 as an encoder connection, note the technical data of the evaluable
encoders at X101; see the chapter
Information
Note that a master encoder must be connected to axis A or terminal X101.
Single-ended HTL incremental encoders
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
—
2
BE2
N channel
3
BE3
A channel
4
BE4
B channel
5
DGND
Reference ground; not bridged with X103,
pin 5
Tab. 125: X101 connection description for single-ended HTL incremental signals, axis A
Single-ended HTL pulse train
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE1
—
2
BE2
—
3
BE3
Frequency
4
BE4
Direction
5
DGND
Reference ground; not bridged with X103,
pin 5
Tab. 126: X101 connection description for single-ended HTL pulse/direction signals, axis A