13 | Diagnostics
STOBER
180
02/2019 | ID 442728.05
13.2.5.2
PROFINET network connection
The Act. and Link LEDs at X200 and X201 on the top of the device indicate the state of the
PROFINET network connection.
Link
Link
2
4
3
1
X200
X201
Act
Act
Fig. 41: LEDs for the state of the PROFINET network connection
1
Green: Link at X201
2
Yellow: Activity at X201
3
Green: Link at X200
4
Yellow: Activity at X200
Green LED
Behavior
Description
Off
No network connection
On
Network connection exists
Tab. 182: Meaning of the green LEDs (Link)
Yellow LED
Behavior
Description
Off
No data exchange
Flashing
Active data exchange with IO controller
Tab. 183: Meaning of the yellow LEDs (Act.)