13.3.27 Event 69: Motor connection
The possible effects depend on the configured level (U12).
§
0: Inactive
§
3: Fault
The drive controller is interrupted if:
§
A29 = 0: Inactive for STOBER device controller
or
§
A540 = 0: disable drive, motor is free to rotate for CiA device controller
Response:
§
The power unit is disabled and axis movement is no longer controlled by the drive controller
§
The brakes are no longer controlled by the drive controller and engage in the event of an
inactive release override (F06)
The drive controller is interrupted with a quick stop if:
§
A29 = 1: Active for STOBER device controller
or
§
A540 = 2: slow down on quick stop ramp for CiA device controller
Response:
§
The axis is stopped by a quick stop; meanwhile, the brakes are controlled by the drive
controller and remain released
§
At the end of the quick stop, the power unit is disabled and axis movement is no longer
controlled by the drive controller; the brakes are no longer controlled by the drive controller
and engage in the event of an inactive release override (F06)
Number
Cause
Check and action
2: No motor connected
Connection error
Check the connection and correct it if
necessary
Defective motor cable
Check the cable and replace it if
necessary
3: Wake and Shake failed
Increased or reduced
mechanical friction
Check the service status of the
mechanics and service them if
necessary
Mechanical block
Check the output and correct the block if
necessary
Tab. 210: Event 69 – Causes and actions