10.4.2
X10: 400 V supply
Terminal X10 is used to connect the supply module to the supply grid.
Conductor cross-sections for the power connection
When selecting the conductor cross-section, note the line fuse, the maximum permitted
conductor cross-section of terminal X10, the routing method and the surrounding temperature.
UL-compliant operation
The chassis of the PS6A/SI6A units is to be bonded through the M6 grounding studs on the
PS6A units (4.0 Nm, 35 Lb.inch).
Size 2
Terminal
Pin
Designation
Function
1 | 2 | 3 | 4
1
L1
Power supply
2
L2
3
L3
4
PE
Grounding conductor
Tab. 85: X10 connection description – Size 2
For connecting wiring, observe the terminal specifications in the chapter
.