6 | Technical data
STOBER
62
02/2019 | ID 442728.05
Resolver
Specification
Resolver signals
U
2
−10 V
DC
to +10 V
DC
I
2max
80 mA
f
2
7 – 9 kHz
P
max
0.8 W
Transfer ratio
0.5 ± 5 %
Number of poles
2, 4 and 6
Signal shape
Sinus
Max. cable length
100 m, shielded
Tab. 56: Specification for resolver signals
HIPERFACE DSL encoders
Specification
HIPERFACE DSL
U
2
12 V
DC
I
2max
250 mA
Encoder design
Single-turn and multi-turn
Max. cable length
100 m, shielded
Tab. 57: Specification for HIPERFACE DSL
Unsuitable encoder models
The following STOBER encoder models may
not
be connected:
Encoder model
Code according to type designation
ECI 1118
C0
EQI 1130
Q0
ECI 1319
CR
EQI 1329
QP
EQI 1331
QR
Tab. 58: Encoder models with unsuitable supply voltage range