STOBER
9 | Installation
02/2019 | ID 442728.05
95
9.6
Installing the DC link connection
Observe the installation notes when installing the DC link connection and associated hardware
components.
9.6.1
Order overview of the components for the DC link
connection
Device
Terminal set
Quick DC-Link
Type
ID No.
ID No.
Type
ID No.
Width [mm]
PS6A24
56650
138660
DL6B20
56656
45
PS6A34
56651
138661
DL6B21
56658
65
SI6A061
56645
138655
DL6B10
56655
45
SI6A062
56646
138656
DL6B10
56655
45
SI6A161
56647
138657
DL6B11
56656
65
SI6A162
56648
138658
DL6B11
56656
65
SI6A261
56649
138659
DL6B11
56656
65
SI6A262
56653
138662
DL6B12
56663
105
SI6A361
56654
138663
DL6B12
56663
105
Tab. 81: Overview of hardware components necessary for the DC link connection with ID No.
9.6.2
Installing the DC link connection
DANGER!
Electrical voltage! Risk of fatal injury due to electric shock!
▪
Always switch off all power supply voltage before working on the devices!
▪
Note the discharge time of the DC link capacitors. You can only determine the absence of
voltage after this time period.
Tools and material
You will need:
§
3 copper rails with sufficient length and a cross-section of 5 x 12 mm, see the chapter
§
The nut and washer assemblies (M5), insulation connection pieces and quick fastening
clamps included with the DL6B Quick DC-Link modules
§
The insulation end sections for the left and right termination of the group that are available
separately
§
Fastening screws and tool for tightening the fastening screws
Requirements and installation
Observe the basic installation instructions in the chapter