12.1 Common faults and solutions
Vehicle lift cannot be raised.
Cause
Solution
No mains power / control power
Check the mains power/control power.
Oil level too low (but motor is running).
Top up oil level.
Overload safety valve opens.
• Vehicle lift overloaded.
• Safety valve fixed incorrectly; let technical
services fix safety valve.
Pump yield too low.
Have the pump replaced by the technical
service department.
Guide pieces at unequal heights (by more
than 60 mm: Control current LED blinks (long
cycle).
Use correction valves to correct, see Code
64 - Master and slave correction on page 48.
Alert technical services if this persists.
Circuit interrupted at highest position:
electrical fault or vehicle lift stays in highest
position.
Lower vehicle lift; check electrical circuit.
Reset the highest position, see Code 60
- Elevation limiter on page 47. Alert the
technical service department if there is an
electrical fault.
Vehicle lift cannot be lowered
Summary of Contents for Freedomlift SK 2055
Page 108: ...Installation and Service Manual 108 SK 2055 2070 2090 14 2 Electrical diagram 3 x 230V ...
Page 109: ...Installation and Service Manual 109 SK 2055 2070 2090 14 3 Electrical diagram 3 x 400V ...
Page 113: ...Installation and Service Manual 113 SK 2055 2070 2090 14 6 Dimensions SK 2055 3 piece arms ...