Installation and Service Manual
48
SK 2055 / 2070 / 2090
If the required elevation is higher than the current setting, deactivate the current
elevation limiter first.
7.2 Code 61 - Automatic lighting
This option can be used to switch the lights on and off at heights below
approximately 500 mm. The lights will turn on and off automatically if
programme 61 is activated.
7.3 Code 62 - Foot protection
This option is used to set the automatic foot protection safety. Activating
programme 62 will cause the vehicle lift to stop lowering at approximately 300
mm. To lower further, the Unlock and Down buttons must be pressed again.
The lowering is then accompanied by an audible alarm.
7.4 Code 64 - Master and slave correction
This option ensures that the unlocking solenoids and the master correction
valve are operated by the Up button, while the unlocking solenoids and the
slave correction valve are operated by the Down button. Furthermore, activating
programme 64 also disables the safe limit monitoring.
This setting remains active for 10 minutes, after which the safe limit monitoring
is automatically reactivated. The setting will not be saved in the EEPROM,
which means that the safe limits will always be active after starting and
stopping.
7.5 Code 65 - Safe limits
This option is available so that the lift can function outside the safe limits (30
and 60 mm). This could be used to make the lift level when outside the safe
limits. Activating programme 65 disables the safe limit monitoring.