7 Programmable settings
In general, programming is done as follows:
1. When turning on the mains switch, press the Unlock button in until 60
(blinking) appears in the display code.
2. Press the Up and Down buttons to select one of the programmes 60
through to 68.
3. Activate a programme by pressing the Lights button. The code is then
displayed continuously. Pressing the Lights button again will cause the
code to blink and inactivate the programme.
4. After all the programmes have been set, exit the programme mode by
pressing the Unlock button again.
The programme mode is automatically terminated if no buttons are pressed for
30 seconds. The control box then enters running mode. The settings are also
stored after a power failure. The default is for the programmes 60 through to 68
to be inactive.
7.1 Code 60 - Elevation limiter
If this code is inactive, the lift will stop at the highest position of the mechanical
limiter in the cylinder. The pressure relief valve is then opened. This will not
damage the lift.
The elevation limiter can be programmed in this way:
1. Position the vehicle lift at the required limiting elevation.
2. Allow the lift to lower onto the safety locks, then raise the lift 20 to 30 mm to
ensure that the highest elevation is not exactly the same as the safety lock
position.
3. Activate programme 60.