Installation and Service Manual
35
SK 2055 / 2070 / 2090
8. Check with a level that also the supports are at the same height. The post
may recline max. 12 mm backward. If required adjust with shims.
9. Tighten the nuts with a torque of 80 Nm (SK 2055) or 150 Nm (SK 2070
and SK 2090).
Never tighten the nuts before the stipulated hardening time for the chemical
anchors has elapsed.
10. After load testing the vehicle lift, tighten the anchor bolts again to a torque
of 80 Nm (SK 2055) or 150 Nm (SK 2070 and SK 2090).
Summary of Contents for Freedomlift SK 2055
Page 108: ...Installation and Service Manual 108 SK 2055 2070 2090 14 2 Electrical diagram 3 x 230V ...
Page 109: ...Installation and Service Manual 109 SK 2055 2070 2090 14 3 Electrical diagram 3 x 400V ...
Page 113: ...Installation and Service Manual 113 SK 2055 2070 2090 14 6 Dimensions SK 2055 3 piece arms ...