Installation and Service Manual
63
SK 2055 / 2070 / 2090
Take care when fitting hydraulic components. All components must be free
of dirt. Use clean UNIL HVC SX 15 oil for the hydraulic system, filtered at a
maximum of 4 microns.
1. Remove the hydraulic unit housing (the housing is secured by two safety
bolts).
2. Measure the distance between the fixture points for the overhead wiring in
the posts and adjust the horizontal connecting tube (1) to the correct length,
if necessary.
Summary of Contents for Freedomlift SK 2055