4.2.
ON-SITE PREPARATION
4.2.1.
ELECTRICAL NETWORK
The system is linked to the mains power supply via a cable with
2
or
3
wires + ground connected to the controller.
Various power supply voltages are possible: 200V, 208V, 230V, 400V, 440V, 480V (50/60Hz) ± 10 %. The choice
of the power supply voltage and the type of network (single phase or three-phase) depend on the option selected
and the type of arm used.
When making the connections, the ground wire must be connected first.
Power rating to be installed:
Minimum wire cross section: 14 AWG / 2 mm
2
Maximum wire cross section: 8 AWG / 6 mm
2
(flex wire)
Maximum wire cross section: 7 AWG / 10 mm
2
(solid wire)
Maximum tightening torque applicable on terminal block screw: 1.8 Nm
Note:
The controller is fitted with a filter to limit the induced disturbances (disturbances caused by the
controller). The filter can cause major leakage current peaks that have to be taken into account
when selecting the elements protecting the power supply circuit (using a time delay ground fault
circuit breaker). Leakage current can reach up to
250 mA
for
3 ms
. Nominal leakage current for
3-phase and single phase configurations is below
3 mA
.
CAUTION:
Make sure that the voltage supplied corresponds to the voltage shown on the manufacturer's
plate of the
CS8C
controller.
TX40
1,5 kVA
TX60
1,7 kVA
TX90
2 kVA
RX160
3 kVA
RS40B, 60, 80
1,7 kVA
DANGER:
Use a cable whose cross-section is suitable for the power rating shown on the
manufacturer's plate and protect the line accordingly.
Summary of Contents for CS8C
Page 1: ...CS8C Controller Instruction manual D28070504A 26 03 2009 CS8C St ubli 2009...
Page 4: ...St ubli 2009 D28070504A CS8C 4 248...
Page 6: ...St ubli 2009 D28070504A CS8C 6 248...
Page 8: ...St ubli 2009 D28070504A CS8C 8 248...
Page 9: ...CS8C St ubli 2009 D28070504A 9 248 Chapter 1 Introduction CHAPTER 1 INTRODUCTION...
Page 10: ...St ubli 2009 D28070504A CS8C 10 248...
Page 13: ...CS8C St ubli 2009 D28070504A 13 248 Chapter 1 Introduction...
Page 14: ...St ubli 2009 D28070504A CS8C 14 248...
Page 16: ...St ubli 2009 D28070504A CS8C 16 248...
Page 20: ...St ubli 2009 D28070504A CS8C 20 248...
Page 21: ...CS8C St ubli 2009 D28070504A 21 248 Chapter 3 Safety CHAPTER 3 SAFETY...
Page 22: ...St ubli 2009 D28070504A CS8C 22 248...
Page 31: ...CS8C St ubli 2009 D28070504A 31 248 Chapter 3 Safety...
Page 32: ...St ubli 2009 D28070504A CS8C 32 248...
Page 33: ...CS8C St ubli 2009 D28070504A 33 248 Chapter 4 Installation CHAPTER 4 INSTALLATION...
Page 34: ...St ubli 2009 D28070504A CS8C 34 248...
Page 43: ...CS8C St ubli 2009 D28070504A 43 248 Chapter 4 Installation Holder measurements Figure 4 5...
Page 52: ...St ubli 2009 D28070504A CS8C 52 248...
Page 53: ...CS8C St ubli 2009 D28070504A 53 248 Chapter 5 Integration CHAPTER 5 INTEGRATION...
Page 54: ...St ubli 2009 D28070504A CS8C 54 248...
Page 77: ...CS8C St ubli 2009 D28070504A 77 248 Chapter 5 Integration Figure 5 13 Switches...
Page 81: ...CS8C St ubli 2009 D28070504A 81 248 Chapter 5 Integration Figure 5 14 Switches...
Page 111: ...CS8C St ubli 2009 D28070504A 111 248 Chapter 5 Integration...
Page 112: ...St ubli 2009 D28070504A CS8C 112 248...
Page 113: ...CS8C St ubli 2009 D28070504A 113 248 Chapter 6 Operation CHAPTER 6 OPERATION...
Page 114: ...St ubli 2009 D28070504A CS8C 114 248...
Page 153: ...CS8C St ubli 2009 D28070504A 153 248 Chapter 6 Operation...
Page 154: ...St ubli 2009 D28070504A CS8C 154 248...
Page 155: ...CS8C St ubli 2009 D28070504A 155 248 Chapter 7 PC utilities CHAPTER 7 PC UTILITIES...
Page 156: ...St ubli 2009 D28070504A CS8C 156 248...
Page 161: ...CS8C St ubli 2009 D28070504A 161 248 Chapter 7 PC utilities...
Page 162: ...St ubli 2009 D28070504A CS8C 162 248...
Page 163: ...CS8C St ubli 2009 D28070504A 163 248 Chapter 8 Maintenance CHAPTER 8 MAINTENANCE...
Page 164: ...St ubli 2009 D28070504A CS8C 164 248...
Page 243: ...CS8C St ubli 2009 D28070504A 243 248 Chapter 8 Maintenance...
Page 244: ...St ubli 2009 D28070504A CS8C 244 248...
Page 245: ...CS8C St ubli 2009 D28070504A 245 248 Chapter 8 Maintenance APPENDIX...