Version 5.2
Sourcefire 3D System Installation Guide
180
Hardware Specifications
Sourcefire 8000 Series Devices
Chapter 6
The power supply modules are located on the rear of the appliance. The
table describes the LEDs associated with the
management interface.
The
8000 Series RJ45 to DB-9 Adapter Pin-Out
table list the signals on a typical
DB-9 serial connector and the corresponding pins on the device’s RJ45 serial
connectors. You can use this table to construct an adapter for serial connections.
8000 Series Power Supply LEDs
LED
D
ESCRIPTION
Off
The power supply is not plugged in.
Amber
No power supplied to this module.
OR
A power supply critical event such as module failure, a
blown fuse, or a fan failure; the power supply shuts down.
Blinking amber
A power supply warning event, such as high temperature
or a slow fan; the power supply continues to operate.
Blinking green
AC input is present; volts on standby, the power supply is
switched off.
Green
The power supply is plugged in and on.
8000 Series RJ45 to DB-9 Adapter Pin-Out
DB-9 P
IN
S
IGNAL
D
ESCRIPTION
RJ45 P
IN
1
DCD/DSR
Data carrier detect/data set ready
7
2
RD
Receive data
6
3
TD
Transmit data
3
4
DTR
Data terminal ready
2
5
GND
Ground
4 & 5
6
No connection
7
RTS
Request to send
1