
Version 5.2
Sourcefire 3D System Installation Guide
134
Hardware Specifications
Sourcefire Defense Centers
Chapter 6
The
DC1500 Serial Port Pin Assignments
table describes the signal present on
the DB-9 connector.
DC1500 Physical and Environmental Parameters
The
DC1500 Physical and Environmental Parameters
table describes the physical
attributes and the environmental parameters for the appliance.
DC1500 Serial Port Pin Assignments
P
IN
S
IGNAL
D
ESCRIPTION
1
DCD
Carrier detect
2
RD
Received data
3
TD
Transmitted data
4
DTR
Data terminal ready
5
GND
Ground
6
DSR
Data set ready
7
RTS
Request to send
8
CTS
Clear to send
9
RI
Ring indicator
DC1500 Physical and Environmental Parameters
P
ARAMETER
D
ESCRIPTION
Form factor
1U
Dimensions (D x W x H)
27.2 in.x 16.93 in. x 1.7 in. (69.1 cm x 43.0 cm x 4.3 cm)
Max weight
34 lbs. (15.4 kg)
Power supply
600 W power supply for 120 VAC
9.5 Ampere maximum at 110 volts, 50/60 Hz
4.75 Ampere maximum at 220 volts, 50/60 Hz
Operating temperature
50°F to 95°F (10°C to 35°C)
Non-operating temperature
-40°F to +158°F (-40°C to +70°C)