Version 5.2
Sourcefire 3D System Installation Guide
166
Hardware Specifications
Sourcefire 7000 Series Devices
Chapter 6
Four 1000BASE-T Copper Interfaces
Use the following table to understand the link and activity LEDs on copper
interfaces.
Use the following table to understand the bypass LED on copper interfaces.
SFP Interfaces
You can install up to eight hot-swappable Sourcefire SFP transceivers, available in
1G copper, 1G short range fiber, or 1G long range fiber. SFP transceivers do not
have bypass capability and should not be used in intrusion prevention
deployments. See
Using SFP Transceivers on a 3D7115 or 3D7125
Link LED
Activity LED
Bypass LED
3D7115 and 3D7125 Copper Link/Activity LEDs
S
TATUS
D
ESCRIPTION
Both LEDs off
The interface does not have link.
Link amber
The speed of the traffic on the interface is 10Mb or
100Mb.
Link green
The speed of the traffic on the interface is 1Gb.
Activity blinking
green
The interface has link and is passing traffic.
3D7115 and 3D7125 Copper Bypass LED
S
TATUS
D
ESCRIPTION
Off
The interface pair is not in bypass mode or has no power.
Steady green
The interface pair is ready to enter bypass mode.
Steady amber
The interface pair has been placed in bypass mode and is
not inspecting traffic.
Blinking amber
The interface pair is in bypass mode; that is, it has failed
open.