6-8
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
6-2. Servo/EQ Alignment after Replacing the Drum
6-2-1. Drum Phase Adjustment
For 525/60 Video System
1.
Select the 525/60 system for the unit.
If the 625/50 system is selected, switch the unit to the 525/60 system by setting basic menu item 013,
525/625 SYSTEM SELECT referring to the operation manual, Section 7-2-2. Then turn the power
off and on again.
Important
Switching the system results in all signal data on the disk being lost.
2.
Prepare the alignment tape SR2-1 which was cued up to 00:25:00:00 of time-code in advance.
3.
Press S1101 on the SS-63 board to enter the maintenance mode.
4.
Select M0:TAPE MAINTENANCE.
5.
Select A0:SERVO ADJUST.
6.
Select A00-01:SERVO ADJUST.
.
An inserted tape will be ejected automatically at the time.
7.
Select A011:RF SWITCHING POS..
8.
Select AUTO by shifting the cursor
*
.
9.
Insert the SR2-1 and press SET button. Then;
.
Automatic drum phase adjustment will be started.
.
After the adjustment is normally completed, the message “ADJUST COMPLETE” will be displayed
on the video monitor.
10. Press the MENU button to return to SERVO ADJUST display.
11. Select A012:NV-RAM CONTROL.
12. Execute “SAVE ALL ADJUST DATA”.
.
After saving operation is normally completed, the message “DATA SAVED” will be displayed on
the video monitor.
For 625/50 Video System
13. Switch the unit to the 625/50 system by setting basic menu item 013, 525/625 SYSTEM SELECT
referring to the operation manual, Section 7-2-2. Then turn the power off and on again.
14. Prepare the alignment tape SR2-1P which was cued up to 00:25:00:00 of time-code in advance.
15. Press S1101 on the SS-63 board to enter the maintenance mode.
16. Select M0:TAPE MAINTENANCE.
17. Select A0:SERVO ADJUST.
18. Select A00-01:SERVO ADJUST.
.
An inserted tape will be ejected automatically at the time.
19. Select A011:RF SWITCHING POS..
20. Select AUTO by shifting the cursor
*
.
21. Insert the SR2-1P and press SET button. Then;
.
Automatic drum phase adjustment will be started.
.
After the adjustment is normally completed, the message “ADJUST COMPLETE” will be displayed
on the video monitor.
22. Press the MENU button to return to SERVO ADJUST display.
23. Select A012:NV-RAM CONTROL.
24. Execute “SAVE ALL ADJUST DATA”.
.
After saving operation is normally completed, the message “DATA SAVED” will be displayed on
the video monitor.
25. Return the unit to its normal system by setting basic menu item 013, 525/625 SYSTEM SELECT.