6-22
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
6-3. Analog Video Playback System Adjustment after Replacing the Drum
(4) Change the connection of the oscilloscope as follows:
CH-1:
TP5/DM-89(D-1), GND: E702/DM-89(D-1)
CH-2:
TP305/DM-89(C-4), GND: E303/DM-89(B-1)
(5) OXIDE C adjustment
Playback the pulse & bar signal portion (9:00 to 11:00) of the alignment tape CR5-2A or CR5-2A PS,
and perform the adjustment.
(DNW-A100/A50/A45: CR5-2A, DNW-A100P/A50P/A45P: CR5-2A PS)
Adjustment point:
1
RV307/DM-89(F-5) and
1
RV308/DM-89(F-5)
Specification:
B
>
35 dB
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
(6) Eject the alignment tape CR5-2A/CR5-2A PS.
(7) METAL C adjustment
Playback the flat field signal portion (24:00 to 26:00) of the alignment tape CR5-1B or CR5-1B PS,
and perform the adjustment.
(DNW-A100/A50/A45: CR5-1B, DNW-A100P/A50P/A45P: CR5-1B PS)
Adjustment point:
1
RV305/DM-89(F-4) and
1
RV306/DM-89(F-5)
Specification:
C
>
40 dB
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
(8) Stop the playback of the alignment tape CR5-1B/CR5-1B PS.
B
4.9 MHz
fc
2fc
9.8 MHz
B
fc
4.9 MHz
2fc
9.8 MHz
C
fc
5.8 MHz
2fc
11.6 MHz
C
fc
6.7 MHz
2fc
13.4 MHz