3-70
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
3. METAL C Adjustment
n
Connection of the oscilloscope remains unchanged.
1.
During play back the alignment tape in PLAY mode,
adjust the level difference between the fc and 2fc on
the spectrum analyzer.
PB portion:
Flat field signal (24:00 to 26:00) of
CR5-1B (NTSC) / CR5-1B PS (PAL)
Adj. points:
1
RV305/DM-89(F-4) and
1
RV306/DM-89(F-5)
Specification: C
>
40 dB
2.
Stop the playback of the alignment tape.
4. METAL Y Adjustment
1.
Change the connection of the oscilloscope as follows:
CH-1: TP4/DM-89(E-1), GND: E702/DM-89(D-1)
CH-2: TP105/DM-89(G-4), GND: E105/DM-89(G-1)
2.
During play back the alignment tape in PLAY mode,
adjust the level difference between the fc and 2fc on
the spectrum analyzer.
PB portion:
Flat field signal (24:00 to 26:00) of
CR5-1B (NTSC) / CR5-1B PS (PAL)
Adj. points:
1
RV105/DM-89(F-4) and
1
RV106/DM-89(F-5)
Specification: D
>
40 dB
3.
Stop the playback of the alignment tape.
n
It is not necessary to eject the alignment tape when
perform subsequent “3-8-10. Demodulator Limiter
Balance Adjustment”.
NTSC model
PAL model
C
fc
6.7 MHz
2fc
13.4 MHz
C
fc
5.8 MHz
2fc
11.6 MHz
NTSC model
PAL model
D
fc
8.9 MHz
2fc
17.7 MHz
D
fc
7.6 MHz
15.3 MHz
2fc
3-8. Analog Betacam PB System Alignment
3-8-8. OMC Carrier Balance Adjustment