6-10
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
6-2. Servo/EQ Alignment after Replacing the Drum
6-2-3. Recording Current Adjustment
1.
Select A12:REC CURRENT.
2.
Select AUTO by shifting the cursor
*
in A12:REC CURRENT menu.
3.
Press SET button.
.
An inserted alignment tape will be ejected automatically at the time.
.
The message “Insert Blank Tape” will be displayed on the video monitor.
4.
Insert a recording tape. Then;
.
Automatic recording current adjustment will be started.
.
After the adjustment is normally completed, the message “Auto Adjust Complete” will be displayed on the video
monitor.
5.
Return to the operation mode by pressing MENU button four times.
6.
Eject the recording tape.
7.
Press S1101 on the SS-63 board to enter the maintenance mode.
8.
Select M0: TAPE MAINTENANCE.
9.
Select A1: RF ADJUST.
10. Select A1F: NV-RAM CONTROL.
11. Execute “SAVE ALL ADJUST DATA”.
.
After saving operation is normally completed, the message “Save Complete” will be displayed on the video monitor.
12. Return to the operation mode by pressing MENU button four times.