1-1
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
Section 1
Service Overview
Board name
Ref. No. (address)
Description
Part No.
Remarks
AD-105 board
PS500 (B-7)
Fuse (chip) 2 A, 125 V
!
1-533-351-11
For BKNW-104
PS501 (B-7)
APR-12 board
PS900 (F-7)
Fuse (chip) 0.5 A, 125 V
!
1-533-271-21
APR-13 board
PS700 (G-7)
Fuse (chip) 0.5 A, 125 V
!
1-533-271-21
CP-297 board
PS100 (C-1)
Fuse (chip) 1 A, 125 V
!
1-533-380-21
PS101 (C-1)
CP-300 board
PS100 (A-1)
Fuse (chip) 1 A, 125 V
!
1-533-380-21
For BKNW-103
PS101 (A-1)
DEC-65 board
PS901 (C-6)
Fuse (chip) 4 A, 125 V
!
1-533-272-11
For BKDW-505/506 (UC)
IC link (chip) 4 A
!
1-533-348-11
For BKDW-506 (CE)
DIF-42 board
PS500 (G-5)
Fuse (chip) 1 A, 125 V
!
1-533-380-21
PS501 (G-6)
DIF-44 board
PS401 (G-7)
Fuse (chip) 0.5 A, 125 V
!
1-533-271-21
For BKNW-105
DPR-71 board
PS11
(G-7)
Fuse (chip) 4 A, 125 V
!
1-533-272-11
PS12
(G-7)
PS13
(H-7)
PS15
(E-7)
DPR-73 board
PS100 (E-7)
Fuse (chip) 4 A, 125 V
!
1-533-272-11
PS101 (E-7)
PS102 (D-7)
DR-315 board
PS1
(A-5)
Fuse (chip) 5 A, 125 V
!
1-533-275-21
EQ-56 board
PS1
(G-7)
IC link (chip) 4 A
!
1-533-348-11
SE-378 board
F1
Fuse (chip) 2 A, 125 V
!
1-533-351-11
F3
F2
Thermal fuse 115
d
C
, 3 A, 125 V
!
1-533-251-11
F4
SS-63 board
PS100 (E-7)
Fuse (chip) 3.15 A, 125 V
!
1-533-266-11
PS101 (E-7)
Fuse (chip) 0.5 A, 125 V
!
1-533-271-21
SSX-1 board
PS100 (F-7)
Fuse (chip) 5 A, 125 V
!
1-533-275-21
PS101 (F-7)
Fuse (chip) 2 A, 125 V
!
1-533-351-11
PS400 (F-2)
TBC-23 board
PS1
(C-7)
Fuse (chip) 0.5 A, 125 V
!
1-533-271-21
TC-96 board
PS200 (D-1)
Fuse (chip) 0.4 A, 125 V
!
1-533-724-11
PS300 (D-1)
VPR-17 board
PS900 (H-12)
Fuse (chip) 5 A, 125 V
!
1-533-275-21
Note: (address) means the mounted address of fuse or IC link.
Fuses or IC links for circuit protection are mounted on the
boards of the VTR and on the optional boards.
A fuse or IC link will blow when abnormality occurs and
an over-current flows (or over-heat occurs) in the equip-
ment. Be sure to replace it with the specified fuse or IC
link as shown below after tracing and removing the root of
the fuse-blowing.
c
Use the specified part only
The fuse and IC link are critical parts to safe operation.
Replace these components with Sony parts whose part
numbers appear in this manual published by Sony. If not,
this may cause a fire or electric shock. Be sure to use the
specified component in this manual
1-1. Circuit Protection Device (Fuse and IC Link)