3-44
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
3-7-8. Preparation in Another System
m
.
Be sure to perform the adjustments in the another system
after completing the adjustments in the standard system.
.
The settings of the VTR’s switches are the same as the
Preparation in standard system.
For the DNW-A100/A50/A45
1.
Wait more than 30 seconds after turning off the
POWER switch.
2.
Stop the extending of the VPR-17 board.
3.
Turn on the POWER switch
4.
Return the following SUB-ITEM settings of the
ITEM-709 and -723 in the setup extend menu to the
customer settings.
.
709 : CAV LEVEL FORMAT
1. OUTPUT CAV LEVEL
.
713 : VIDEO SETUP REFERENCE LEVEL
4. OUTPUT LEVEL
5.
Turn the video system to a 625/50 system using the
setup menu ITEM-013 : 525/625 SYSTEM SELECT.
(Refer to Section 7-2-2 of the operation manual.)
6.
Set the analog composite monitor to the PAL mode.
For the DNW-A100P/A50P/A45P
1.
Wait more than 30 seconds after turning off the
POWER switch.
2.
Stop the extending of the VPR-17 board.
3.
Turn on the POWER switch
4.
Turn the video system to a 525/60 system using the
setup menu ITEM-013 : 525/625 SYSTEM SELECT.
(Refer to Section 7-2-2 of the operation manual.)
5.
Set the analog composite monitor to the NTSC mode.
6.
Set the ITEM-709 and -713 in the setup extended
menu as follows:
ITEM No.
Customer
Setting at
SUB-ITEM
setting
adjustment
1. OUTPUT CAV LEVEL
_________
8
B-CAM
713 : VIDEO SETUP REFERENCE LEVEL
4. OUTPUT LEVEL
_________
8
0.0%
3-7. Video System Alignmnet (VPR-17 Board)
3-7-8. Preparation in Another System