213
Video/Audio Signal Adjustments and Settings
Chap
te
r 3
O
per
at
ion
s
You can also close the menu by pressing the same ACCESS button again.
Making the Gradation of SDI Input Signals Appear Smooth
(When Using a Serial Digital Interface Module or HD Serial
Digital Interface Module)
Apply dynamic rounding to video signals input from an SDI or HD SDI
connector to make the gradation appear smooth.
Dynamic rounding is applied by default. If you do not want to apply dynamic
rounding, set this setting to [Off].
1
Press the ACCESS button in the same column as the selection button for the
video signal you want to adjust.
2
In the top menu, select [Dynamic Rounding], and confirm.
The setting turns on or off each time it is selected.
3
Press the ESC button to close the ACCESS menu.
If dynamic rounding is not performed, the video gradation will have visible
contouring artifacts because this unit drops the lower 2 bits of 10 bit SDI or HD
SDI input signals.
Converting 4:3 Source Materials to Wide Screen
Configure the following settings to convert 4:3 input materials to wide screen
when the PGM output aspect ratio is set to 16:9 SD or 16:9 HD mode.
1
Press the ACCESS button in the same column as the selection button for the
video you want to configure.
2
In the top menu, select [Wide Zoom] to set it [On], and confirm.
The setting turns on or off each time it is selected.
You cannot confirm this setting in the source viewer.
3
Press the ESC button to close the ACCESS menu.
Note
Note
Caution
Luminance Level
100%
Chroma Level
100%
Dynamic Rounding
Off
Luminance Level
100%
Chroma Level
100%
Wide Zoom
On
Summary of Contents for Anycast station AWS-G500
Page 44: ...Chapter 1 Overview 44 Names and Functions of Parts ...
Page 76: ...Chapter 2 Preparations 76 Settings Related To Input Signals ...
Page 268: ...Chapter 3 Operations 268 Activating Each Function Simultaneously With the ON LINE Button ...
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ...Sony Corporation Printed in Japan ...