Deleting Data From the Upstream Appliance
212
SonicWALL CDP 6.0 Administrator’s Guide
Deleting Data From the Upstream Appliance
To delete data and policy information from the upstream appliance, perform the following steps:
Step 1
Login to the downstream CDP appliance using the Web Management Interface.
Step 2
Navigate to the
System > Settings
page and click the
Restore from Offsite
tab.
Step 3
To delete data, select the
Data
checkbox.
Step 4
To delete settings and configurations, select the
Policy
checkbox.
Step 5
Click
Wipe Offsite Data
.
Step 6
A warning message displays. Click
Yes
to continue.
Replacing the Downstream CDP Appliance
If the downstream CDP is no longer accessible, a new CDP can take its place and recover data
from the upstream appliance. The following information is required before you begin:
•
Old CDP’s registration code (to identify the original CDP)
•
Old CDP’s encryption key
•
New CDP’s registration code
To recover data from the upstream CDP appliance, you must first configure the upstream
appliance to allow the new downstream appliance access to the old appliance’s data. Then the
new appliance must be setup to connect to the upstream CDP appliance.
Note
The data on the downstream appliance will be replaced with the data from the upstream
appliance. The data restore process cannot be canceled once it has started.
Summary of Contents for CDP 6.0
Page 15: ...xiv SonicWALL CDP 6 0 Administrator s Guide...
Page 99: ...Creating a Global Policy 84 SonicWALL CDP 6 0 Administrator s Guide...
Page 215: ...Recovering Data from Microsoft SQL Server 200 SonicWALL CDP 6 0 Administrator s Guide...
Page 229: ...Replacing the Downstream CDP Appliance 214 SonicWALL CDP 6 0 Administrator s Guide...
Page 267: ...Contributors 252 SonicWALL CDP 6 0 Administrator s Guide...