background image

MOTOR DRIVES  

FOR LEAF GATES

SGA

 6000

SGA 

6000

 INTÉGRAL

SGA 

6000

 INTÉGRAL +

Summary of Contents for SGA 6000

Page 1: ...MOTOR DRIVES FOR LEAF GATES SGA 6000 SGA 6000 INT GRAL SGA 6000 INT GRAL...

Page 2: ...ETURE AUTO SEQUENTIEL RAZ MEMOIRE STATUT 15 19 14 12 17 6 13 18 16 7 8 20 1 2 3 5 4 TOTAL PIETON RADIO TOTAL FERMETURE AUTO SEQUENTIEL RAZ MEMOIRE STATUT 10 9 11 x 2 SGA 6000 2 1 1 1 INTEGRAL 2 1 1 1...

Page 3: ......

Page 4: ......

Page 5: ...1 17 TOTAL PIETON RADIO TOTAL FERMETURE AUTO SEQUENTIEL RAZ MEMOIRE STATUT 9 8 10 18 15 16 14 13 11 12 5 6 1 2 7 20 19 9 m 2 x 1 mm...

Page 6: ...2 M10 x4 x4 x8 x8 M10 x 150 M6 x 40 M6 HM10 x8 HM6 x4 5 7 8 5 7 8 Not included in the kit...

Page 7: ...ions 5 Product description 6 Preliminary operations 8 5 step installation 1 Preparing and drilling gateposts 12 2 Installing the motors 14 3 Mounting the arms 16 4 Electrical connections 20 5 Settings...

Page 8: ...basis At Somfy the pursuit of quality is a continuous process of improvement Somfy s reputation has been built upon the reliability of its products and the Somfy brand is synonymous with innovation a...

Page 9: ...t a locking device ensure that other people remain at a distance Frequently check the product to detect any defects in balance in the gate or any signs of wear Do not use the motor if it requires repa...

Page 10: ...ection Yes Level of Protection IP 54 Integrated radio receiver Yes Remote controls Radio frequency Range of use Number of controls memorisable 433 42 MHz 30 m 32 Possible connections Orange LED output...

Page 11: ...ance with gate open in mm The motor s electronic unit is fitted with an ambient light detector which detects whether or not the cover is fitted This means that settings mode is only available when the...

Page 12: ...rovided its structure is sufficiently sturdy Brackets n Points to be checked before installing l Checking your gate Your gate is in good condition It will open and close normally without being forced...

Page 13: ...Quality of gateposts surface Gateposts which are not level or have a non flat surface require the use of an intermediate support bearing plate Likewise when the motor fastening lugs do not completely...

Page 14: ...ble between motors 2 x 0 75 mm2 cable between cells 2 3 Flexible ICT duct Power input from mains 3 x 1 5 mm2 24 V connection between the two motors provided 2 x 1 mm2 2 1 3 4 24 V connection between t...

Page 15: ...ion Use appropriate tools as specified on page 2 Handle the motorisation system with caution to avoid injury Do not connect the motor to the mains or the optional backup battery until the mounting pro...

Page 16: ...will be less than the values shown o Dimension measurement o Marking the AM and AH baselines o Drilling the gateposts l Measure dimension A Using the table below determine the maximum opening value of...

Page 17: ...eter 4 or 5 mm concrete drill bit pre drill 4 holes for filling with chemical sealants into each gatepost in the positions marked on the template Finish drilling the 4 holes using a concrete drill bit...

Page 18: ...ng the sealants For dependability SOMFY advises that you fasten the motor using a chemical sealant o Selecting the motors o Applying the sealants o Installing the motors Position the motor on the gate...

Page 19: ...onto the lower threaded rods using the washers and nuts 1 Check that the motors are level Continue tightening if necessary 2 Finish mounting the motor on the upper threaded rods using the washers and...

Page 20: ...grooves are aligned 2 Insert the short shaft The hexagonal head must be fully engaged in the arm 3 o Assembling the arms o Assembling the arms o Mounting the arms on the motors o Mounting the arms on...

Page 21: ...flexible ring in the arm o Mounting the arms on the motors Insert the flexible ring into the arm 2 1 Use the appropriate screw to tightly hold the assembly in place 2 Fit the arm into the motor shaft...

Page 22: ...Drill the leaves using an 8 mm drill bit 4 5 7 8 Through the fastening lug mark the points on the leaf bracket where holes will be drilled 3 Check that the gate is closed and in contact with the stop...

Page 23: ...ening lug Using a mallet drive the bolts all the way into the gate Assemble the fastening lug on the leaves then re install the arms into the fastening lug 5 10 19 17 Self check before the next step D...

Page 24: ...nnections 4 n Steps o Installing the grommets Mount the grommets onto the two motors o Installing the grommets o Connecting the two motors o Connecting the antenna o Connecting the mains power cord o...

Page 25: ...rst and closes last Case 1 Motor M1 operates the left leaf which opens first and closes last Case 2 Motor M1 operates the right leaf which opens first and closes last Motor M1 is always connected to t...

Page 26: ...connection to a solar power supply see page 42 o Locking the arms Close both leaves and push the arms to latch them Never cross the antenna s wire Terminal Blue wire Neutral 15 Red brown black wire Ph...

Page 27: ...tronic unit o Symbols used Short press less than 0 5 seconds 0 5s Led on Long press longer than 0 5 seconds 0 5s Led blinking Led off o Storing the remote controls Do not block the light sensor using...

Page 28: ...to fully open and close the gate with the positions of the end stops During the learning process you should remain at a normal distance from the gate and follow the steps below Press the button stored...

Page 29: ...ut mains power for at least 5 seconds Restore mains power Press the button stored again The leaves MUST continue in the opening direction If the leaf does not open correctly The leaf which moves first...

Page 30: ...ng or full opening see page 30 to activate this mode The gate is opened automatically by pressing the remote control Close the gate by pressing the button again Stop the gate by pressing the button ag...

Page 31: ...ection operation n Area lighting operation In automatic mode the gate closes automatically after 30 seconds If an obstacle is detected the gate stops Area lighting comes on each time the motor is swit...

Page 32: ...sing the central button Three button remote controls or control points cannot be used to open the gate for pedestrian access n Unlocking locking the motor If the motor is placed in the unlocked positi...

Page 33: ...he settings menu If you have stored 32 remote controls and you store a 33rd remote control the first remote control stored will be deleted and so on l Adding 2 or 4 button remote controls l Adding 3 b...

Page 34: ...flashes 2 Press the right hand button The AUTO CLOSE indicator lights up continuously then flashes 3 Press the left hand button once The AUTO CLOSE indicator flashes 2 Access the settings menu see pag...

Page 35: ...TUS indicator flashes 3 Press the left hand button repeatedly until the RESET indicator flashes 2 Access the settings menu see page 29 1 All the remote controls and settings programmed gate travel ope...

Page 36: ...ntrol the motor by pressing another button on the remote control If your motor responds to this action you have stored this button on the remote control Only one button can be stored per remote contro...

Page 37: ...circuit on the electronic unit BUS output terminals 3 4 Check the accessories connected to the electronic unit BUS output 5 Motors thermal protection device activated Allow motors to cool down until t...

Page 38: ...34 34 Accessories Description and connections n Section des c bles par type d accessoire TX RX...

Page 39: ...If the gate is closed and the cells are blocked the gate will not open A set of cells comprises one transmitter cell TX one receiver cell RX l Cell location To simplify the wiring place the receiver...

Page 40: ...he receiver cell indicator does not light up adjust the alignment of the cell RX using a shim Check again If the receiver cell indicator lights up continuously correct alignment refit the receiver cel...

Page 41: ...fore the gate begins to move n Orange light 2400596 Accessories Description and connections 3 4b 1 2 3 3 4a 5 10 9 8 11 6 6 mm 12 mm 7 HO5 RR F 2 x 0 75 mm2 175 mm 60 mm 77mm 24 V E14 22 10 Watt max 6...

Page 42: ...To increase the operation time of the battery during use the wired accessories are deactivated and the gate can only be controlled using the remote controls and the radio control points The STATUS in...

Page 43: ...4 yellow BUS label on the electronic unit This accessory is not compatible with solar power STOP n Wired intercom 2400463 Connect the key switch to terminals 3 and 4 yellow BUS label on the electronic...

Page 44: ...d 2 blue ANT label on the electronic unit the wire core to terminal 1 the ground strap to terminal 2 n Wired keypad 2400581 T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V Connect T1 and C1 of the keypad...

Page 45: ...En g lish Accessories Description and connections n 2 button remote control n External radio code keypad 2400549 2400625 n 4 button remote control n Multi application remote control CODE 2400576 24006...

Page 46: ...leave the gate open during more than 2 days When the motor is operated using solar power the wired controls are deactivated and the gate can only be controlled using the remote controls and the radio...

Page 47: ...h 24V 15W L B S Connect the solar power supply cable to the grey BATT terminal on the motor s electronic unit Connect the area lighting to terminals 5 and 6 n Connection to the solar power supply n Ar...

Page 48: ...eur apporter toutes modifications que nous jugerons utiles SOMFY GMD030110 SOMFY SAS capital 20 000 000 Euros RCS Annecy 303 970 230 Utilisable en UE C Usable in EU C Bruikbaar in EU C Utilizable en l...

Reviews: