5
This pellet-run boiler is intended for residential use, within a protected
environment. Safety systems may intervene to shut down the boiler. If
this occurs, contact technical assistance. In any circumstances should you
attempt to interfere with the safety systems;
The pellet-run boiler is a biomass heating unit equipped with an electric
fume extractor. The occurrence of any power failure during its use may
prevent fume extraction and the room will be filled with smoke. For this
reason, you should have a natural fume extraction system, like a chimney,
available;
Solzaima offers an optional safety system that allows you to connect
your boiler to a UPS unit, thus avoiding problems related to a power
failure and ensuring that the fume extractor will continue to operate under
such conditions until the complete extraction of all fumes;
If you intend to use your boiler when leaving it unattended or while
you are away from home, it is advised that you utilise the safety system
specified above to guarantee its safe functioning in the eventuality of a
power failure;
While in operation, NEVER disconnect the electric plug of your pellet-
run boiler. Seeing as the boiler's fume extractor is power-operated,
disconnecting the plug would prevent the extraction of combustion fumes;
Your unit must be disconnected from the mains for servicing. Before
doing this, the unit must be totally cooled down (if operating before);
Never touch the interior of the boiler without first disconnecting it from
the power mains;
The maximum water temperature (set-point temperature) that the
user can set for the boiler is 80°C. In the event of the boiler reaching a
temperature of 95ºC, it will automatically switch off and activate a
corresponding alarm.