5.3. Installation with a shaft
As shown in Figure 7, the pellet-run boiler is installed with a
100 mm
exhaust pipe directed up the chimney. If the chimney is too large, an 80
mm-wide pipe should be installed at the fume outlet.
A "T"-tube must be attached to the base of the piping to allow for periodic
inspections and annual maintenance, as illustrated in Figure 7.
Figure 7 – Side view of the boiler installation with a shaft, highlighting the
inspection point.
It is recommended that the boiler not be used during adverse weather
conditions that may seriously disrupt the unit's fume extraction capacity
(this is especially the case with very strong winds).
If you do not use the unit for a long time, check it to make sure that the
flue pipes are clear before lighting the fire.