2-39
Using the SunEye
Using the SunEye Extension Kit
Figure
2-60.
Image Processing
Recall that when selecting Extension Kit Mode, Quick Skyline Capture Mode was automatically
selected. In this mode, the image processing has been postponed.
• To process an image on the device, open the unprocessed skyline and press “Process Now” or
press “Process all skylines in session”.
• To process an image on a computer, connect the SunEye via the USB cable and open the SunEye
desktop software. In the “File” menu, select “Transfer from device...”. Skylines are automatically
processed during the transfer. Note that in this case the Skylines are also removed from the de-
vice.
Skylines are automatically corrected for the azimuth and tilt of the device when the image was
snapped. The top of the annual sunpath view is always in the direction that the device was point-
ing when the image was snapped. This azimuth correction may cause a rotation and distortion of
the picture as it is automatically scaled to fit in the display.
It is important to note that the accu-
racy of the azimuth readings and solar access calculations is not affected.
Figure
2-61.
Alternative Measurement Method
An alternative mode of operation for the SunEye Extension Kit is to use a portable computer to
control the SunEye while the pole is extended. This method requires two operators; one to hold
the pole and the other to use the computer to control the SunEye. The portable computer is con-
nected to the SunEye via a long USB cable. A real-time image of the SunEye’s display is shown
Summary of Contents for SunEye 210
Page 1: ...Solmetric SunEye 210 User s Guide Solar Test and Measurement Equipment...
Page 2: ...2 YOUR SK D dZ DISTRIBUTOR SOLIGENT 800 967 6917 www soligent net...
Page 4: ...4...
Page 16: ...1 10 Getting Started System Controls and Settings...
Page 80: ...4 6 Solar Access and Interpretation of Data Numerical Calculations...
Page 90: ...5 10 Maintenance and Troubleshooting Regulatory Compliance...