5-3
Maintenance and Troubleshooting
Compass Calibration
Figure
5-2.
Compass Calibration Menu
4
Perform the calibration as indicated by the directions on the SunEye. The level indicator must be
centered and locked (yellow) for the calibration point to be accepted. Two measurements are
made at positive and negative tilts for the Northern orientation. Tilt the SunEye so that the level
indicator is centered and locked. Figures below are examples of what needs to be performed for
the Northern orientation.
Figure
5-3.
Compass Calibration
Figure
5-4.
Compass Calibration