3 Wiring and Connection
3-2
3. Wiring and Connection
3.1 Main Circuit Wiring
The names and specifications of the main circuit terminals are given below.
Also this section describes the general precautions for wiring and precautions under special environments.
3.1.1 Main Circuit Terminals
: Main circuit terminals
Terminal
Symbols
Name
Specification
L1, L2, L3
Main circuit power
input terminals
Three-phase 200 to 230 V,
+10% to -15% (50/60 Hz)
L1C, L2C
Control power
input terminals
Single-phase 200 to 230 V,
+10% to -15% (50/60 Hz)
B1/
, B2
*1
Regenerative
resistor
connection
terminals
If the internal regenerative resistor is insufficient, connect a regenerative resistor
between B1/
and B2.
If LECYM2-V9 is used, remove the lead or shorting bar between B2 and B3, and
connect a regenerative resistor between B1/
and B2.
Note: The Regenerative resistor is not included.
1,
2
DC reactor
connection
terminal for power
supply harmonic
suppression
The DC reactor connection terminals are short-circuited when the DRIVER is shipped from the
factory:
1 and
2.
B1/
Main circuit
positive terminal
Use when DC power supply input is used.
2 or
Main circuit
negative terminal
U, V, W
Servomotor
connection
terminals
Use for connecting to the servomotor.
Ground terminals
(× 2)
Use for connecting the power supply ground terminal and servomotor ground
terminal.
∗1.
Do not short-circuit between B1/
and B2. It may damage the DRIVER.
Summary of Contents for LECYU Series
Page 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Page 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Page 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Page 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Page 143: ...4 Operation 4 44 ...