5 Adjustments
5-12
(3) Automatically Setting the Notch Filter
Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)
If this function is set to Auto Setting, vibration will be detected automatically and the notch
filter will be set when the tuning-less function is enabled.
Set this function to Not Auto Setting only if you do not change the notch filter setting before
executing tuning- less function.
Parameter
Meaning
When Enabled
Classification
Pn460
n.
口
0
口口
Does not set the 2nd notch filter automatically with
utility function.
Immediately
Tuning
n.
口
1
口口
[Factory setting]
Set the 2nd notch filter automatically with utility
function.
(4) Tuning-less Level Settings
Two tuning-less levels are available: the rigidity level and load level. Both levels can be set in
the Fn200 util- ity function or in the Pn170 parameter.
- Rigidity Level
Parameter
Meaning
When Enabled
Classification
Pn170
n.
口
0
口口
Rigidity level 0 (Level 0)
Immediately
Setup
n.
口
1
口口
Rigidity level 1 (Level 1)
n.
口
2
口口
Rigidity level 2 (Level 2)
n.
口
3
口口
Rigidity level 3 (Level 3)
n.
口
4
口口
[Factory setting]
Rigidity level 4 (Level 4)
- Load Level
Parameter
Meaning
When Enabled
Classification
Pn170
n.0
口口口
Load level : Low (Mode 0)
Immediately
Setup
n.1
口口口
[Factory setting]
Load level : Medium (Mode 1)
n.2
口口口
Low level : High (Mode 2)
5
Summary of Contents for LECYU Series
Page 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Page 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Page 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Page 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Page 143: ...4 Operation 4 44 ...