3 Wiring and Connection
3-40
- Recommended Surge Absorber
The surge absorber (for Lightning surge) absorbs lightning surge and prevents faulty operation in or damage to
electronic circuits.
Main Circuit Power Supply Recommended Surge Absorber
Single-phase 200V
LT-C12G801WS
[by SOSHIN ELECTRIC CO., LTD.]
Three-phase 200V
LT-C32G801WS
[by SOSHIN ELECTRIC CO., LTD.]
- Fixing the Cable
Fix and ground the cable shield using a piece of conductive metal.
• Example of Cable Clamp
- Shield Box
A shield box, which is a closed metallic enclosure, is effective as reinforced shielding against electromagnetic
interference (EMI) from DRIVERs. The structure of the box should allow the main body, door, and cooling unit
to be attached to the ground.
The box opening should be as small as possible.
<Note>
Do not connect the the analog monitor cable to the DRIVER during operations. Connect them only when the
machinery is stopped during maintenance.
Summary of Contents for LECYU Series
Page 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Page 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Page 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Page 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Page 143: ...4 Operation 4 44 ...