3 Wiring and Connection
3-22
3.4 Examples of Connection to PC or PLC...etc
This section shows examples of DRIVER I/O signal connection to the PC or PLC...etc.
3.4.1 Sequence Input Circuit
(1) Photocoupler Input Circuit
CN1 connector terminals 6 to 13 are explained below.
The sequence input circuit interface is connected through a relay or open-collector transistor circuit. When
connecting through a relay, use a low-current relay. If a low-current relay is not used, a faulty contact may result.
Relay Circuit Example
Open-collector Circuit Example
24 VDC
DRIVER
+24 VIN 3.3 k
Ω
/DEC, etc.
24 VDC
DRIVER
+24 VIN 3.3 k
Ω
/DEC, etc.
Note: The 24 VDC external power supply capacity must be 50 mA minimum.
The DRIVER’s input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit
according to the specifications required for each machine.
Note:
-
The connection example in
3.2.3
shows sink circuits.
- The ON/OFF polarity differs between when a sink circuit is connected and when a source circuit is connected.
Sink Circuit
Source Circuit
24 V
+
−
DRIVER input
24 V
+
−
DRIVER input
Input Signal Polarities
Input Signal Polarities
Signal
Level
Voltage
Level
Contact
Signal
Level
Voltage
Level
Contact
ON
Low (L)
level
0 V
Close
ON
High (H)
level
24 V
Close
OFF
High (H)
level
24 V
Open
OFF
Low (L)
level
0 V
Open
Summary of Contents for LECYU Series
Page 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Page 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Page 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Page 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Page 143: ...4 Operation 4 44 ...