- 45 -
1C to
1F
CC-Link
system area
(No used)
-
20 to
2F
30 to
3A
CC-Link
system area
-
3B
Remote
station
READY
● Only at Half numerical data instructions
The content of Remote station READY is as same as
at Single numerical data instructions. Please refer to
the content of Rx1B.
3C to
3F
CC-Link
system area
-
40 to
6F
-
70 to
7A
CC-Link
system area
-
7B
Remote
station
READY
●Only at Full numerical data instructions
The content of Remote station READY is as same as
at Single numerical data instructions. Please refer to
the content of Rx1B.
7C to
7F
CC-Link
system area
-
The table below shows the changes in the output signal with respect to controllers state.
Output signal
State
BUSY
INP
SVRE
Lock
SETON
OUT0 to 5
Controller powered down [SVOFF] with no
motion
OFF
OFF
OFF
Lock
OFF
OFF
Controller powered down [SVON] with no
motion
OFF
OFF
ON
Release
OFF
OFF
During returning to origin [SETUP].
ON
OFF
ON
Release
OFF
OFF
The electric actuator is at the origin. On
completion of [SETUP]
OFF
ON
*1
)
ON
Release
ON
OFF
During movement by positioning / pushing
operation.
ON
OFF
ON
Release
ON
ON
*2
)
The electric actuator is paused by [HOLD]
OFF
OFF
ON
Release
ON
ON
*2
)
On completion of the positioning
operation.
OFF
ON
*4
)
ON
Release
ON
ON
*2
)
Stopped due to pushing a work-load in
pushing operation.
OFF
ON
ON
Release
ON
ON
*2
)
Stopped due to no detection of work-load
during a pushing operation.
OFF
OFF
ON
Release
ON
OFF
On completion of return to origin and then
with [SVON] turned off.
OFF
OFF
*4
)
OFF
Lock
ON
ON
*3)
EMG signal stop from the CN1 connector
after the electric actuator is at the origin.
OFF
OFF
*4
)
OFF
Lock
ON
OFF
*1) The output turns on when the electric actuator is within the range defined in the basic parameter setup.
*2) The output is updated on the transition
of (ON→OFF) of the DRIVE input signal.
*3) Retains the previous state.
*4) The output turns on when the electric actuator is "In position" of the step data.
(No used)