![SMC Networks LECPMJ Series Operation Manual Download Page 32](http://html1.mh-extra.com/html/smc-networks/lecpmj-series/lecpmj-series_operation-manual_1299638032.webp)
- 31 -
Controller
power supply
6.4 Stop circuits
When the external switch to stop or the stop switch of the teaching box is enabled on this controller, the
electric actuator will stop.
(1) Example circuit 1- Single controller with teaching Box
When the teaching box is connected to the controller, the te
aching box’s stop switch will become
effective.
Warning
The teaching box’s stop switch is effective only to the controller that is connected with it.
24V
0V
Controller
CN4
CN1
Power supply plug
EMG
C 24V
M 24V
0V
External stop circuit
Stop signal
Teaching box is not
connected.
Teaching box is
connected.
Teaching box
(with 3m cable)
Stop switch