![SMC Networks LECPMJ Series Operation Manual Download Page 58](http://html1.mh-extra.com/html/smc-networks/lecpmj-series/lecpmj-series_operation-manual_1299638058.webp)
- 57 -
7
7 to 0
DATA (L)
Alarm 1
● Half numerical data instructions
Data that corresponds to the executed
instruction code is output.
00h is output when there is an abnormality. *
3)
● Full numerical data instructions
Alarm code shown as a 3 digit decimal number
when numerical data reading is enabled and an
alarm is generated. In the half numerical data
instruction mode, up to two alarms can be
output. In the full numerical data instruction
mode, up to four alarms can be output.
The latest alarm code generated will be output to
alarm 1. Alarm is updated by another alarm. The
code of the previous alarms generated will be
shifted to alarm1
→
2
→
3
→
4.
When the number of alarms generated exceeds
the maximum alarm output for each mode, the
oldest alarm code is deleted from the record.
Example)
Alarms were generated in order of (1)
→
(5)
Alarm 1
(The latest)
(1)
(2)
(3)
(4)
(5)
Alarm 2
0
(1)
(2)
(3)
(4)
Alarm 3
0
0
(1)
(2)
(3)
Alarm 4
0
0
0
(1)
(2)
(1) to (5) in the table indicate the codes for the
generated alarms.
Please refer to
"16.1 Alarm details"
for the alarm
details.
F to 8
Alarm 2
8
7 to 0
Alarm 3
F to 8
Alarm 4
9
F to 0
Sub Function
The executed instruction code is output. Please
refer to
“
9.5 Data editing function
"
for details of
the instruction code.
The value of 80h that is the OR (logical add) is
output to Sub Function which set in RWw1.
*3)
10
F to 0
Address
The start address of the executed instruction code
is output. Please refer to
“
9.5 Data editing
function
"
for details of the instruction code.
00h is output in abnormal conditions.
*3)
11
F to 0
Address
(always 0)
0 is always output
12
F to 0
DATA (H)
The data of the executed instruction code is
output.
Error code is output in abnormal conditions.
*3)
13
F to 0
DATA (L)
The data of the executed instruction code is
output. 00h is output in abnormal conditions.
*3)
14
F to 0
Occupation
area
-
15
F to 0
H=Most Significant Byte or upper word
L=Least Significant Byte or lower word
*3) When the error occurred in the data edit function by the specified address which is out of the range etc.,
the value of 80h that is the OR (logical add) is output to Sub Function which set in RWw1 is returned to
Sub Function RWr3 (RWr9 at Full numerical data instructions), and the received error code is returned
to DATA (H) [RWr6] (RWrC at Full numerical data instructions). And RWr4:Address and RWr7: DATA
(L) ( RWrA and RWrD at Full numerical data instructions) will be 00h. Error code is shown below.