Table 5-8
Get Chassis Power Policy
Request Data
1
0xae
2
Version
0 for this specification
Response Data
1
Completion Code
2
0xae
3
Power policy:
[0]: payload power auto on
0: payload power remains off when the DC input power is turned
on,
until a power on command or button event is received
1: payload power is turned on automatically when the DC input
power is turned on
[1]: payload power off after power loss
0: Bit 0 of this policy takes the payload power control after a power
loss event
1: Bit 0 of this policy is ignored, and the payload power remains
off
when the DC input power gets recovered from an unexpected
power loss event. An explicit power on command or button event
is
required to turn on the payload power.