Site Preparation
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
87
The Extreme Edge Server is designed for installation in an IP55/IP65 19" outdoor cabinet
and is compliant to an IP20 Ingress Protection Rating.
External air filtering may be needed if installed in a location other than an IP55/IP65
cabinet.
2.7.2
Electronic Waste Disposal
Alway dispose used blades, system components, and batteries according to your country’s
legislation and manufacturer’s instructions.
2.8
Regulatory Compliance
The Extreme Edge Server complies with the following standards:
Humidity range
5% to 95% noncondensing
Operating Altitude
-60m to 1800m without temperature derating, up to 4000m with
temperature derating of 1C per 300m above 1800m
Operating Vibration
GR-3108-CORE Class 2 vibration
Table 2-3
Environmental Conditions (continued)
Characteristic
Condition
Table 2-4
Regulatory Standards
Standard
Description
ULCSA 60950-1
EN 60950-1
IEC 60950-1 CB Scheme
Safety requirements
Directive (EU) 2015/863
(amending Annex II to Directive
2011/65/EU)
Directive on the restriction of the use of certain
hazardous substances in electrical and electronic
equipment (RoHS)
EN 55032 Class A (EU)
EN 55024 (EU)
FCC 47 CFR Part 15 Subpart B (US), Class
A
ETSI EN 300 386 Class A
EMC requirements
Telcordia GR-1089-CORE
Electromagnetic Compatibility and Electrical
Safety-Generic Criteria for Network
Telecommunications Equipment, Issue 6