102
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
Software Configuration
Software Configuration
Here,
<BIOS image>.fri
is the firmware file to which BIOS is upgraded. The following
screen shows a typical output when the above command is executed.
After completion of this procedure the image is copied to the flash temporary location. Once
the upgrade procedure shows the result as
Success
(as notified in the above screen), the
upgrade procedure would complete with the rebooting of the system. After the reboot, the
CPU boots with the updated BIOS.
After the system boots to Linux, confirm that the BIOS has upgraded:
fcu –q
command.
5.2.1.2.3
CPLD Upgrades
There are two CPLD components that can be updated using HPM.1 upgrade tool: the Glue
CPLD and the CPU CPLD. The CPU CPLD may also be upgraded using the fcu utility.
Use the following commands for HPM.1 upgrade.
Glue CPLD Upgrade
ipmitool -I lanplus -U admin -P admin -H 192.168.201.9 -z 0x7fff hpm
upgrade mc1600-cpld-glue-x.x.x.hpm activate
CPU CPLD Upgrade
ipmitool -I lanplus -U admin -P admin -H 192.168.201.9 -z 0x7fff hpm
upgrade mc1600-cpld-cpu-x.x.x.hpm activate
NOTICE
Do not reset or reboot the system at this point in time. This may corrupt the BIOS.
Once the upgrade is successful, the system automatically resets and boots with the
upgraded BIOS.