System Overview
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
79
Enable all on-board DC-DC converter for CPU complexes
Implementation of power-up timing sequence requirements
Supervision of power rails for CPU complex
I
2
C slave interface connected the BMC
–
Power control of both CPUs
–
Power fail registers for both CPUs
–
Control and status registers for each CPU
–
Error status registers for each CPU
LPC target interface for each CPU
–
Port 0x80 for each CPU, select CPU via SMBus register
–
SERIRQ for KCS interrupt support
–
Control and status registers
–
Can be used to update configuration of the logic device
1.13.2
Glue CPLD
The Glue CPLD on the Extreme Edge Server runs off management power and is
associated with the BMC and is powered anytime -48V power is present. It implements
these major functions:
Monitor output of low-temperature thermal switch
Enable BMC power under appropriate operating conditions
Implement power-up timing sequence requirements for non-CPU power rails
Supervision of non-CPU power rails
Enable on-board clocks when payload power is stable
I
2
C slave interface connected the BMC
Update configuration of the logic device via I
2
C interface
Reset control
BMC serial routing, routes 1 UART from each CPU to BMC
Control debug LEDs via registers
Watchdog timer
LPC slave interface connected to CPU1
Implement status and control registers for SFP+ modules