Software Configuration
MC1600 Extreme Edge Server Installation and Use (6806870A02B)
103
NOTE:
The activation command will fail if the payload power is on. However, there is a
known issue that the CPLD upgrade will fail if the payload power is off. This means
you will do the CPLD firmware upgrade when the payload power is on, and then
perform a system power cycle to activate the new Glue and / or CPU CPLD
firmware.
5.2.1.2.4
CPU CPLD Upgrade Using fcu Utility:
Query Operation
To find the current CPLD version before upgrading it with a new version, use the following
command:
$
fcu -q
The following screen shows a typical output when the
$
fcu -q
command is executed.
Show Operation
Verification of CPLD Firmware Image
fcu -vf <Fri file image>
is the command used for verifying a CPLD firmware image.
The following screen shows an example output of the command.
Summary of Contents for MC1600
Page 1: ...MC1600 Extreme Edge Server Installation and Use P N 6806870A02B January 2020...
Page 8: ...List of Figures 8 MC1600 Extreme Edge Server Installation and Use 6806870A02B...
Page 24: ...24 MC1600 Extreme Edge Server Installation and Use 6806870A02B Safety Notes Safety Notes...
Page 125: ...1...