MC1600 Extreme Edge Server Installation and Use (6806870A02B)
Safety Notes
Safety Notes
Use only shielded cables when connecting peripherals to help assure that appropriate radio
frequency emissions compliance is maintained. For proper EMC shielding, only operate the
system with face plates installed and all vacant slots covered or populated with filler cards.
Grounding
If the product is not properly grounded, it may be damaged by electrostatic discharge.
The system contains EMI gaskets at the shelf and module level. Make sure that each of the
system's parts contact the EMI gasket.
The shelf is also fitted with an ESD jack/snap for use with conductive wrist straps. Make
sure the operator uses proper ESD protection.
This is a Class A product based on the standard of the Voluntary Control Council for
Interference by Information Technology Interference (VCCI). If this equipment is used in a
domestic environment, radio disturbance may arise. When such trouble occurs, the user
may be required to take corrective actions.
The equipment is suitable for installation in a Common Bonding Network (CBN) or Isolated
Bonding Network (IBN).
System Installation
System Damage
To avoid system damage verify that the system environment meets the environmental and
power requirements given in this manual before installing the system. Before you set up
and cable your new system, consider these guidelines:
Restricted access location: Intended for installation in a restricted access location
with access by trained personnel only.
Detachable power supply cord set: The detachable power supply cord set is not
included in shipment. The detachable power supply cord set shall be an approved
type, acceptable to the authorities in the country where the equipment is installed.
Installation codes: Where applicable, this unit shall be installed in accordance with
the National Electrical Code (NEC).
Overcurrent protection: A readily accessible listed branch circuit overcurrent
protective device must be incorporated into the building wiring. For appropriate
AWG rating of the overcurrent protection device, see NEC Table 310.16 and other
national regulations.
The protective bonding conductor depends on your power distribution topology.
Make sure that you use an appropriate protective bonding conductor regarding the
rating of the branch circuit protection.