7.11 SENSORS REPLACEMENT
X AXIS SENSOR REPLACEMENT (CARRIAGE SENSOR)
1) turn off the machine and disconnect from the power supply.
2) gain access to the bottom compartment (Ch. 7.4).
3) use the pliers to disconnect the X axis sensor connector (Q1) from the board (Fig. 88).
4) cut the 2 wiring clips (Q2).
6) remove the faulty sensor from its support and screw in the new one, then secure the support with the new
sensor by tightening the 2 screws (W1).
secure with the nut (W) and lock nut.
8) connect the sensor connection (Q1) to the board and secure the sensor wiring with a new clip.
9) proceed to Maintenance > Machine zeroes (Ch. 5.8.2).
10) replace the bottom plate.